20% OFF shipping at www.randa.lt on orders over $79 + up to 10% OFF products
www.randa.lt
home > 133819-01 Bently Nevada 3500/60 Temperature Module | New Stock > 133819-01 Bently Nevada 3500/60 Temperature Module | New Stock
download picture
133819-01 Bently Nevada 3500/60 Temperature Module | New StockBently Nevada 3500 60 133819 01 Temperature Monitor I O Module Configured for high precision temperature data acquisition in the 3500 Machinery Protection System, the Bently Nevada 133819 01 (3500 60 Temperature Module) provides direct physical electrical execution. This 6 channel component functions as the physical interface layer that routes and processes signals from field mounted Resistance Temperature Detectors (RTDs) and Thermocouples (TCs) into
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Bently Nevada 3500/60 133819-01 Temperature Monitor I/O Module

Configured for high-precision temperature data acquisition in the 3500 Machinery Protection System, the Bently Nevada 133819-01 (3500/60 Temperature Module) provides direct physical/electrical execution. This 6-channel component functions as the physical interface layer that routes and processes signals from field-mounted Resistance Temperature Detectors (RTDs) and Thermocouples (TCs) into the main monitoring rack.

Hardware Specifications

Parameter Specification
Model 3500/60 (Part Number: 133819-01)
Brand Bently Nevada (Baker Hughes)
Origin USA
Weight 0.46 kg (1.0 lb)
Dimensions 24.2 cm x 11.2 cm x 2.6 cm
Operating Temp -30 to +65 deg C
Power Consumption Power supplied via main rack backplane
Channel Count 6 independent channels
Supported Inputs RTDs: 3-wire and 4-wire (Pt, Cu, Ni); TCs: Type J, K, E, T, R, S, B
Input Impedance Greater than 10 Mohm
Isolation Non-isolated (Internal common ground)
Recorder Outputs 4-20 mA or 1-5 VDC (User-configurable per channel)
A/D Resolution 16-bit
Update Rate All channels updated within 250 ms
Storage Temperature -40 to +85 deg C

Machinery Monitoring & Cross-Talk Suppression

The 6-channel architecture uses a 16-bit analog-to-digital converter to track thermal variations on bearings, windings, and process loops. Because this specific iteration is a non-isolated hardware design sharing an internal common ground, the layout incorporates advanced hardware filters to maximize cross-talk suppression between adjacent probe lines. This design prevents high-frequency electromagnetic interference (EMI) from motor circuits or turbine environments from generating measurement drift, maintaining signal integrity over the 250 ms continuous conversion cycle.

Frequently Asked Questions

Q: Can a single 133819-01 module accept mixed RTD and Thermocouple field lines concurrently?

A: Yes. Each of the 6 independent channels is individually programmable via the 3500 Rack Configuration Software. You can configure any combination of supported 3-wire/4-wire RTDs and standard Thermocouples across the terminal matrix.

Q: What restrictions exist regarding hot-swapping the 133819-01 component?

A: This rear I/O module does not support hot-swapping while the 3500 chassis backplane is energized. Power to the rack must be completely isolated before extracting or inserting the card to avoid transient power surges that could damage the unisolated internal multiplexing circuits.

Field Installation Guidelines

  • Chassis Card Guide Alignment: Insert the module into the rear slot of the 3500 rack directly behind the corresponding 3500/60 monitor module. Press firmly until the multi-pin array fully engages with the passive backplane. Secure the hardware by completely tightening the two integrated mechanical panel fasteners.
  • Shield Grounding Regulations: Terminate all field sensor cable shields at the single-point instrumentation ground rail inside the monitoring panel. Do not ground shields at both ends, as the non-isolated architecture makes the loop highly susceptible to circulating ground currents.
  • Cable Pathway Rules: Route low-voltage RTD and Thermocouple conductors through dedicated instrument wireways. Maintain appropriate physical clearance from high-voltage alternating current (AC) power lines and variable frequency drive cables to minimize noise injection.
  • Thermal Management Clearances: Ensure that the enclosure layout does not block vertical convection airflow through the 3500 rack structure, keeping localized ambient temperatures strictly below the +65 deg C operating threshold.

133819-01 Bently Nevada 3500/60 Temperature Module | New Stock

Item no : 40086353041
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 27 - Jul 2

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches