20% OFF shipping at www.randa.lt on orders over $79 + up to 10% OFF products
www.randa.lt
home > 5466-257 Woodward Analog I/O Module | New & Original Stock > 5466-257 Woodward Analog I/O Module | New & Original Stock
download picture
5466-257 Woodward Analog I/O Module | New & Original StockWoodward 5466 257 MicroNet Plus Series The Woodward 5466 257, also cataloged as the 5466 257 Analog Input Output Module, operates as a dedicated hardware component for precision signal acquisition and actuator control within MicroNet and MicroNet Plus platforms. Hardware Specifications Parameter Specification Model 5466 257 Brand Woodward Origin United States Weight 1. 0 kg Dimensions 160 mm x 120 mm x 40 mm Operating Temp 20 to +70 deg C Power
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Woodward 5466-257 MicroNet Plus Series

The Woodward 5466-257, also cataloged as the 5466-257 Analog Input/Output Module, operates as a dedicated hardware component for precision signal acquisition and actuator control within MicroNet and MicroNet Plus platforms.

Hardware Specifications

Parameter Specification
Model 5466-257
Brand Woodward
Origin United States
Weight 1.0 kg
Dimensions 160 mm x 120 mm x 40 mm
Operating Temp -20 to +70 deg C
Power Consumption 24 VDC Nominal (Accepts 18 to 32 VDC)
Module Type High-Density Analog Input/Output (I/O)
Analog Inputs 8 Channels (Software configurable for 4-20 mA, 0-5 VDC, or +-5 VDC)
Analog Outputs 4 Channels (4-20 mA proportional drive)
Conversion Resolution 12-bit to 16-bit (Configurable via GAP software)
Total Accuracy +-0.1% of Full Scale at room temperature
Galvanic Isolation Full channel-to-channel and channel-to-system isolation
Diagnostics Integrated self-test logic with front-panel LED indicators

Industrial Drives & Governors Properties

The Woodward 5466-257 is engineered with specific thermal heat sink dissipation profiles to prevent thermal drift across its 8 input and 4 output conversion stages. Designed to operate within demanding gas and steam turbine environments, the module coordinates direct actuator loop feedback response paths, establishing deterministic update rates with minimal latency. Internal software configurations handled via GAP (Graphical Application Program) control the 12-bit to 16-bit resolution tracking parameters, optimizing the module's electronic data pathway to eliminate signal jitter during real-time valve position adjustment loops.

Frequently Asked Questions

Q: How do the front-panel LED indicators assist with field diagnostic routines? A: The onboard integrated self-test logic constantly cross-checks module health against the central processing unit. The front-panel Status and Fault LEDs change illumination states immediately if an internal data error, conversion failure, or hardware fault occurs.

Q: Is this module compatible with both MicroNet and MicroNet Plus chassis configurations? A: Yes, the 5466-257 is standardized for installation in both the legacy MicroNet and the updated MicroNet Plus high-density rack platforms, matching standard physical slot tolerances and power distribution paths.

Q: Does the channel isolation protect against ground loops across independent field instruments? A: Yes, the module features full channel-to-channel and channel-to-system galvanic isolation. This architecture physically isolates the electrical paths of each analog line, keeping transient noise or voltage offsets on one field sensor loop localized.

Field Installation Guidelines

  • Module Insertion: Align the module circuit board with the upper and lower slot tracks of the MicroNet rack. Press firmly to slide the module back until the plug-in connectors mate with the active backplane. Lock the front panel fasteners down to establish a rigid ground path.
  • Cable Shield Grounding: Implement twisted, shielded pairing for all field input and output signal lines. Terminate the wire shields at the designated instrumentation tie point inside the terminal cabinet enclosure to prevent stray inductive coupling.
  • Low-Voltage Routing Constraints: Segregate the 4-20 mA and VDC lines from high-current AC motor supply circuits and inductive relay coils. Use distinct wire trays or internal routing barriers to block electromagnetic induction fields.
  • Output Impedance Boundaries: Verify that the loop resistance for the 4-20 mA proportional output actuator paths does not exceed the driving capabilities specified under the nominal 24 VDC system rail envelope.

5466-257 Woodward Analog I/O Module | New & Original Stock

Item no : 84657208727
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 4 - Jul 9

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches